Part Number Hot Search : 
NT68520 PP1101SC LU4S041B 54150 2SB1571 SMDC150F 2SB1571 11974
Product Description
Full Text Search
 

To Download SMI10-5-I38 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  for more information, please visit the product page | for information on related products, view dc power jacks ????????? ?????????????????? cui .com 04/25/2016 1 of 4 series : smi10-usb description: ac-dc power supply model output voltage output current output power ripple and noise 1 effciency level (vdc) max (a) max (w) max (mvp-p) SMI10-5-I38 5 2 10 300 vi notes: 1. at full load, 25c, nominal input, 20 mhz bandwidth oscilloscope, output parallel with 0.1 f and 10 f capacitors to ground. features ? up to 10 w continuous power ? doe level vi, coc tier 2, erp stage 2 ? no load power consumption < 0.1 w ? universal input voltage range ? interchangeable ac blades for global use ? over voltage and short circuit protections ? ul/cul, gs, rcm, ccc, pse safety approvals part number key base number reserved for custom confgurations smi10 - 5 - x - i38 - cxx usb type a inlet output voltage blades: v = north america, europe, united kingdom, australia, and china blade included n = north america blade included e = europe blade included b = united kingdom blade included a = australia blade included c = china blade included k = no blades included date page
for more information, please visit the product page | for information on related products, view dc power jacks ?????????????????? cui .com date 04/25/2016 page 2 of 4 cui inc series : smi10-usb description: ac-dc power supply input parameter conditions/description min typ max units voltage 90 264 vac frequency 47 63 hz current at nominal input voltage 0.3 a leakage current at nominal input voltage & frequency 0.25 ma no load power consumption at 115/230 vac, 60/50 hz 0.075 w output parameter conditions/description min typ max units load regulation 5 % start-up time 3 s hold-up time at nominal input voltage, full load 5 ms protections parameter conditions/description min typ max units over voltage protection with zener clamp 10 vdc over current protection output shut down, auto recovery 4 a short circuit protection safety & compliance parameter conditions/description min typ max units isolation voltage input to output at 10 ma for 1 minute 3,000 4,242 vac vdc safety approvals ul/cul, gs, rcm, ccc, pse emi/emc fcc part 15b class b, ce mtbf as per telcordia sr-332 issue 2, at 115/230 vac, full load, 0 ~ 40c 50,000 hours rohs 2011/65/eu environmental parameter conditions/description min typ max units operating temperature 0 40 c storage temperature -20 60 c operating humidity non-condensing 20 85 % storage humidity non-condensing 5 95 %
for more information, please visit the product page | for information on related products, view dc power jacks ?????????????????? cui .com date 04/25/2016 page 3 of 4 cui inc series : smi10-usb description: ac-dc power supply mechanical parameter conditions/description min typ max units dimensions 60.9 x 38 x 29.2 mm inlet plug interchangeable blades (north america, europe, uk, australia, china) weight without interchangeable blades 40 g mechanical drawing units: mm pin output voltage 1 +5v 2 short 3 short 4 gnd 1 +5 4 gnd interchangeable blades blade designator n e b a c region north america europe uk australia china blade accessory smi-us-3l smi-eu-3l smi-uk-3l smi-au-3l smi-cn-3l blade
for more information, please visit the product page | for information on related products, view dc power jacks ????????? date 04/25/2016 page 4 of 4 cui inc series : smi10-usb description: ac-dc power supply this device complies with part 15 of the fcc rules. operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. cui offers a one (1) year limited warranty. complete warranty information is listed on our website. cui reserves the right to make changes to the product at any time without notice. information provided by cui is believed to be accurate and reliable. however, no responsibility is assumed by cui for its use, nor for any infringements of patents or other rights of third parties which may result from its use. cui products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. a critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safet y or effectiveness. headquarters 20050 sw 112th ave. tualatin, or 97062 800.275.4899 fax 503.612.2383 cui .com techsupport@cui.com rev. description date 1.0 initial release 04/25/2016 the revision history provided is for informational purposes only and is believed to be accurate. revision history


▲Up To Search▲   

 
Price & Availability of SMI10-5-I38

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X